Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Year range
1.
Braz. dent. j ; 34(4): 150-157, July-Aug. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1520332

ABSTRACT

Abstract This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.


Resumo Este estudo teve como objetivo avaliar a influência do formato do arquivo nos parâmetros de qualidade de imagem (ruído de imagem, brilho e uniformidade) de radiografias periapicais adquiridas com diferentes sistemas digitais. As imagens radiográficas de um fantoma de acrílico foram adquiridas com dois sistemas digitais - Digora Toto e Express, e exportadas em cinco formatos de arquivo diferentes - TIFF, BMP, DICOM, PNG e JPEG. O ruído da imagem, o brilho da imagem (média dos valores de cinza) e a uniformidade da imagem (desvio padrão dos valores de cinza) foram avaliados em todas as imagens. A análise de variância (ANOVA) bidirecional com o teste post-hoc de Tukey foi aplicada para comparar os resultados, considerando os formatos de arquivo e os sistemas radiográficos como os fatores estudados. Um nível de significância de 5% foi adotado para todas as análises. O formato de arquivo de imagem DICOM apresentou menor ruído de imagem, maior brilho (maiores valores médios de cinza) e maior uniformidade de imagem (p<0,001) do que os outros formatos de arquivo, que não diferiram entre si para ambos os sistemas de radiografia digital (p>0,05). O sistema Express apresentou menor ruído de imagem e maior uniformidade de imagem que o sistema Digora Toto, independentemente do formato do arquivo de imagem (p<0,001). Além disso, o Express mostrou maior brilho do que o Digora Toto para todos os formatos de arquivo de imagem (p<0,001), exceto para o formato de arquivo de imagem DICOM, que não diferiu significativamente entre os sistemas de radiografia digital testados (p>0,05). O formato de arquivo de imagem DICOM mostrou menor ruído de imagem, maior brilho e maior uniformidade de imagem do que os outros formatos de arquivo (TIFF, BMP, PNG e JPEG) em ambos os sistemas de radiografia digital testados.

2.
Braz. dent. j ; 34(1): 39-44, Jan.-Feb. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1420574

ABSTRACT

Abstract The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Resumo Objetivou-se avaliar a influência do uso excessivo de uma placa de fósforo fotoestimulável (PSP) na densidade, ruído e contraste das radiografias. Foram adquiridas radiografias de um bloco de acrílico com uma PSP do sistema intraoral Express para avaliar a densidade e o ruído da imagem. Inicialmente, cinco imagens foram obtidas e exportadas (primeiro grupo). Após 400 exposições aos raios X e escaneamentos, outras cinco imagens foram obtidas e exportadas (segundo grupo). O mesmo procedimento foi feito após 800 (terceiro grupo), 1200 (quarto grupo), 1600 (quinto grupo) e 2000 aquisições (sexto grupo), resultando em 30 imagens a serem avaliadas. A média e o desvio padrão dos valores de cinza foram calculados para as imagens usando o software ImageJ. Para análise de contraste, foram adquiridas radiografias de uma escala de alumínio com uma nova PSP seguindo os mesmos intervalos de aquisição. A porcentagem de variação do contraste foi calculada. Outras duas PSP sem uso prévio foram utilizadas para avaliar a reprodutibilidade dos métodos. A comparação dos resultados entre os grupos de aquisição foi realizada pela Análise de Variância one-way (α=0,05). O Coeficiente de Correlação Intraclasse (ICC) avaliou a reprodutibilidade dos receptores. O ruído da imagem não diferiu entre os grupos (p>0,05). Houve um leve aumento na densidade após 400 aquisições e uma pequena diferença no contraste para todos os grupos de aquisição sem padrão de aumento ou diminuição (p<0,05). O ICC mostrou excelente confiabilidade para os métodos. Portanto, o uso excessivo da PSP afetou levemente a densidade e o contraste radiográfico.

3.
Braz. dent. j ; 33(1): 31-40, jan.-fev. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1364482

ABSTRACT

Abstract This study aimed to assess the effect of the MAR tool on the expression of artefacts in different regions of a tooth restored with different types of metal posts. Alveolar sockets (anterior, and posterior region) of a mandible and an unirradicular tooth were used. Cone beam computed tomography scans of the tooth without a metal post, and with cobalt-chromium (Co-Cr), nickel-chromium (Ni-Cr), or silver-palladium (Ag-Pd) were individually obtained, with 2 MAR conditions: disabled, and enabled. In an axial reconstruction, lines of interest (LOIs) were set around the canal: 4 in oblique (mesiobuccal, distobuccal, mesiolingual, distolingual) directions, and 4 in orthogonal (mesial, distal, buccal, lingual) directions. Beam-hardening artefacts expression was determined by calculating the difference in the mean of gray values (DMGV) between the experimental and control groups for each LOI. There was no significant difference in the DMGV values between "without MAR" and "with MAR" for any LOI, in neither anterior nor posterior mandible (p>0.05), for the Ni-Cr and Co-Cr groups. For the Ag-Pd, significant differences in the DMGV values were observed between "without MAR" and "with MAR" for most LOIs (p<0.05), mainly in oblique directions in the anterior region, and mesio-distal direction in the posterior region. MAR acted mostly in hypodense artefacts (negative DMGV). The effectiveness of the MAR tool of the OP300 CBCT unit varied according to the post material tested. It was effective in reducing the expression of artefacts raised by the Ag-Pd post, mainly in the tooth regions affected by hypodense artefacts, regardless of the mandibular region.


Resumo O objetivo nesse estudo foi avaliar o efeito da ferramenta de redução de artefato (FRA) na expressão de artefatos em diferentes regiões de um dente restaurado com diferentes tipos de pinos metálicos. Foram usados ​​alvéolos (regiões anterior e posterior) de uma mandíbula e um dente unirradicular. Imagens de tomografia computadorizada de feixe cônico do dente sem pino metálico intracanal e com pinos de cobalto-cromo (Co-Cr), níquel-cromo (Ni-Cr) ou prata-paládio (Ag-Pd) foram individualmente obtidas, com 2 condições de FRA: desativada e ativada. Em uma reconstrução axial, linhas de interesse (LOIs) foram definidas ao redor do canal: 4 em direções oblíquas (mésio-vestibular, disto-vestibular, mésio-lingual e disto-lingual) e 4 em direções ortogonais (mesial, distal, vestibular e lingual). A expressão dos artefatos de endurecimento do feixe foi determinada pelo cálculo da diferença na média dos valores de cinza (DMVC) entre os grupos experimental e controle para cada LOI. Não houve diferença significativa nos valores de DMVC entre as condições "sem FRA" e "com FRA" para nenhuma das LOIs, nem na região anterior nem na região posterior da mandíbula (p>0,05), para os grupos Ni-Cr e Co-Cr. Para o Ag-Pd, diferenças significativas nos valores de DMVC foram observadas entre "sem FRA" e "com FRA" para a maioria das LOIs (p<0,05), principalmente nas direções oblíquas na região anterior, e na direção mesio-distal na região posterior. A FRA atuou principalmente em artefatos hipodensos (DMVC negativos). A eficácia da FRA disponível no aparelho de TCFC OP300 variou de acordo com o material do pino testado. Ela foi efetiva na redução da expressão de artefatos originados por pinos de Ag-Pd, principalmente nas regiões do dente afetadas por artefatos hipodensos, independentemente da região mandibular.

4.
Dental press j. orthod. (Impr.) ; 27(3): e2220422, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1384696

ABSTRACT

ABSTRACT Objective: This study aimed to evaluate and compare pain intensity and Oral Health-related Quality of Life (OHRQoL) in women with temporomandibular disorder (TMD) before (T1) and during (T2) COVID-19 pandemic. Materials and Methods: Sample was composed of forty-one female participants with painful TMD, who presented for TMD treatment. Subjects were asked to indicate their pain intensity and to answer the Oral Health Impact Profile-14 (OHIP-14). Participants data were collected twice: T1 (evaluation of medical records fulfilled before COVID-19 pandemic) and T2 (by means of an online form). Socio-demographic data were assessed in T1. Statistical analysis was performed with a significance level of 5% (Wilcoxon, chi-square or Fisher's exact tests, multiple linear regressions). Results: No difference was found in pain intensity (p=0.26) and OHIP-14 global scores (p=0.53). Physical pain (p=0.03) and social disability (p=0.05) domains improved. In T1, subject's occupation was associated with OHIP-14 global score, physical pain, and physical disability domains. In T2, age was associated with OHIP-14 global scores as well as physical pain, psychological discomfort, and psychological disability domains. Conclusion: COVID-19 pandemic did not worsen pain intensity and OHRQoL in women with painful TMD, and it is suggested that socio-demographic characteristics influenced TMD patients coping skills during pandemic.


RESUMO Objetivo: O presente estudo objetivou avaliar e comparar a intensidade da dor e a Qualidade de Vida Relacionada à Saúde Bucal (QVRSB) de mulheres com disfunção temporomandibular (DTM), antes (T1) e durante (T2) a pandemia de COVID-19. Métodos: A amostra foi composta por quarenta e uma mulheres com DTM dolorosa, que se apresentaram para manejo da DTM. As participantes informaram a intensidade da dor por meio de escala numérica, e responderam ao questionário Perfil de Impacto na Saúde Oral - 14 (Oral Health Impact Profile, OHIP-14). Os dados das participantes foram coletados duas vezes: T1 (avaliação de prontuários odontológicos preenchidos previamente à pandemia de COVID-19) e T2 (por meio de formulário on-line). Dados sociodemográficos foram coletados em T1. A análise estatística foi realizada com nível de significância de 5% (testes de Wilcoxon, qui-quadrado ou exato de Fisher, e regressões lineares múltiplas). Resultados: Nenhuma diferença foi encontrada para a intensidade da dor (p = 0,26) e o escore global do OHIP-14 (p = 0,53). Os domínios relativos à dor física (p = 0,03) e incapacidade social (p = 0,05) melhoraram. Em T1, a ocupação das participantes foi associada ao escore global do OHIP-14 e aos domínios de dor e incapacidade física. Em T2, a idade foi associada aos escores globais do OHIP-14, bem como aos domínios dor física, desconforto psicológico e incapacidade psicológica. Conclusão: A pandemia de COVID-19 não piorou a sensibilidade à dor e a QVRSB das mulheres com DTM dolorosa, e as características sociodemográficas influenciaram suas habilidades de enfrentamento.

5.
Rev. cir. traumatol. buco-maxilo-fac ; 18(3): 26-30, jul.-set. 2018. ilus
Article in Portuguese | BBO, LILACS | ID: biblio-1254651

ABSTRACT

A displasia óssea florida (DOFL) é uma lesão fibro-óssea relativamente incomum dos maxilares, que acomete, principalmente, mulheres melanodermas de meia idade e geralmente é diagnosticada em radiografias de rotina. O presente trabalho tem como objetivo relatar o caso de uma paciente de 50 anos de idade, melanoderma, encaminhada ao Curso de Odontologia da Universidade Federal do Ceará para avaliação imaginológica. Clinicamente, não foi observada nenhuma alteração de volume de estruturas faciais ou intraorais. A radiografia panorâmica evidenciou imagens radiopacas circunscritas por halos radiolúcidos, localizadas bilateralmente em região edêntula de corpo mandibular, sugestivas de DOFL. Na tomografia computadorizada de feixe cônico (TCFC), observaram se áreas hiperdensas em regiões mandibulares edêntulas, sem expansão de corticais ósseas vestibulares e linguais, e recobertas por fina espessura de tecido ósseo, típicos da displasia. Diante do diagnóstico clínico-imaginológico de DOFL, a paciente foi encaminhada para tratamento odontológico multidisciplinar. Por meio da TCFC, foi possível se estabelecer um plano de tratamento que consistiu em procedimentos minimamente intervencionistas, considerando os aspectos clínicos e imaginológicos das lesões observadas. Em sumário, o presente trabalho reforça a importância do exame clínico meticuloso aliado à avaliação por meio de TCFC, com fins de embasar um plano de tratamento adequado em casos de DOFL assintomáticos... (AU)


Florid osseous dysplasia (FOD) is a fibrous lesion relatively uncommon of maxillary bones, mainly affects middle-age black women and generally is diagnosed on routine radiographs. This paper aims to report a case of black woman, aged 50 years, referred to Dentistry Faculty of Federal University of Ceará for imaging evaluation. Clinically, there were no facial or intraoral structures alterations. Panoramic radiography showed radiopaque images circumscribed by radiolucent halos, located bilaterally in the edentulous mandibular body region suggestive of FOD. Cone beam computed tomography (CBCT) showed hyperdense areas in edentulous mandibular regions, with no expansion of buccal and lingual cortical bone, and covered by fine thickness of bone tissue, characteristic of FOD. After the clinical-imaging diagnosis of FOD, the patient was referred for multidisciplinary dental treatment. Through the CBCT, it was possible to establish a treatment plan that consisted of minimally interventional procedures considering the clinical and imaging limits of the observed lesions. In summary, the present case emphasizes a meticulous clinical examination along with an evaluation by means of CBCT allowing an adequate treatment plan for asymptomatic FOD... (AU)


Subject(s)
Humans , Female , Middle Aged , Cementoma , Clinical Diagnosis , Diagnosis, Differential , Cone-Beam Computed Tomography , Fibrous Dysplasia of Bone , Wounds and Injuries , Radiography, Panoramic , Dental Care , Jaw , Maxilla
SELECTION OF CITATIONS
SEARCH DETAIL